    High Configuration Modular Data Center With In Row Precision AC Units

    Ask Lasest Price
    Brand Name : COOLNET
    Certification : CE,ISO
    Price : 1800-30000USD
    Payment Terms : T/T, L/C
    Supply Ability : 300 PCS PER MONTG
    Delivery Time : 10-25 working days
    • Product Details
    • Company Profile

    High Configuration Modular Data Center With In Row Precision AC Units

    High Configuration High Efficient Modular Data Center With In-Row Precision AC Units


    Product Introduction

    In response to the development trend of cloud computing, virtualization, centralization, and high-density servers, standardization is becoming a popular trend in the field of modern data centers. coupling. Integrate subsystems such as power supply and distribution, cooling, cabinets, air enclosures, integrated wiring, and dynamic environment monitoring to improve the overall operation efficiency of the data center, achieve rapid deployment, flexible expansion, save costs, occupy space, and improve the performance of key infrastructure , efficiency and reliability.


    Feature & Benefits

    Advantages

    Intelligent Fire Safe System

    Alerts personnel and drops ceiling panels based on temperature to enable fire suppressions system in the room toextinguish the fire. Once fire signal alarm in room, the top plate will open automatically, and fire extinguishing gasesan enter the aisle.


    Efficiency Flexibility

    Increases the capacity of the air conditioner by supplying a warmer return air temperature. It supports for varying aislewidths, rack heights, rack depths, and single rows. Supports hot and cold aisle containment.


    Automatical Door Structure

    One-way locking door or safe slide doors secures the hot aisle while allowing for quick exit in case of emergency, thesliding door can be closed automatically, can be installed door access system and can be opened from inside to outside if an emergency occurs.

    Main Basic Unit Introduction


    Rack Part

    The modular data center can be configured with N cabinets, including server cabinets, network cabinets and integrated wiring cabinets.

    Appearance of the cabinet

    The cabinet size of the modular data center configuration is uniform, the cabinet conforms to the IEC60297-1 standard, and the front and rear air ducts are adopted. The appearance of the cabinet is shown in the figure.


    Cabinet Charaectristic

    (1) The ventilation rate of the front and rear doors is 70%.

    (2) Two vertical PDUs can be installed at the rear of the cabinet.

    (3) The exact position of each "U" is marked on the vertical installation column of the cabinet. The front door, back door and side panels of the cabinet can be locked and can only be opened with the provided special key


    Aisle Containment -Modular design

    The Aisle of the modular data center is mainly composed of end doors and skylights.


    End gate

    (1) The end doors of the aisle are divided into sliding doors and double doors, which can be selected according to customer needs.

    (2) Sliding door size: height × width × depth = 2050mm × 1200mm × 42mm.
    The sliding door adopts a sliding structure, the cabinet is used as the carrier, and the upper and lower rails are installed to ensure the independence of the closed channel system. The door panel is bent from 1.5mm cold-rolled steel plate, and tempered glass is installed in the middle to ensure the visibility of the area in the passage.
    Adopting modular unit design concept, each unit can be installed and disassembled independently, and can be closely connected with adjacent units, which is convenient for disassembly and assembly; at the same time, it is also suitable for maintenance and management of other equipment on the channel.

    Good sealing
    All unit modules in the hot and cold aisle system are connected precisely, and the parts are sealed with good sealing tops or sponge strips, which not only maintains the aesthetics, but also prevents the leakage of cold air in the cold aisle.

    Technical Specification

    Equipment SystemItemParameter
    SystemDimension1200mm enclosed cold/hot aisle dual-row cabinets
    1200mm enclosed cold/hot aisle Single-row cabinets
    Rack QuantityDual Row Racks:≤48,Single Row Racks:≤24
    RackDimensions600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
    Protection ClassIP20
    Enclosed AisleSkylight300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
    Power Supply and DistributionDimension600mm(W)*1200mm(D)*2000mm(H)
    UPS Power Supply380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
    Battery40AH~240AH/12V Valve Regulated Lead Acid Battery
    CoolingIndoor Unit Size300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
    Cooling CapacityCooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
    Power Supply3Phase 380VAC,50Hz
    Air SupplyFront Supply
    TypeEnclosed Hot/Cold Aisle
    ProtectionIP20
    Monitoring SystemMonitoringTemperature and humidity, smoke detection, smart access control, camera, water leakage alarm
    Equipment monitoringPower supply, battery, power distribution, air conditioning