Sign In | Join Free | My burrillandco.com
Home > In Row Air Conditioning Unit >

20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling

Hefei Coolnet power Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling from wholesalers
     
    Buy cheap 20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling from wholesalers
    • Buy cheap 20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling from wholesalers
    • Buy cheap 20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling from wholesalers
    • Buy cheap 20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling from wholesalers
    • Buy cheap 20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling from wholesalers
    • Buy cheap 20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling from wholesalers

    20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling

    Ask Lasest Price
    Brand Name : COOLNET
    Model Number : XR023A, XR040A
    Certification : CE,ISO
    Price : 1800-30000USD
    Payment Terms : T/T, L/C
    Supply Ability : 300 PCS PER MONTG
    Delivery Time : 10-25 working days
    • Product Details
    • Company Profile

    20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling

    Multiple Air Return Condition Containerized Data Center In-Row Air Cooling Unit


    Product Introduction

    In-row air conditioners are also called in-row air cooling units, or in-row refrigeration units. They are precision refrigeration systems specifically designed for high-heat-density racks. They are placed directly between the rows of server cabinets and dissipate heat directly near the heat source. Generally, the compressors of air-cooled in-row airconditioning units use variable-capacity digital scroll compressors, and the fans use EC fans. The whole machine can adjust the cooling capacity output according to the heat load in the channel. In-row air cooling units are widely used in places, such as condition containerized data centers, various modular data centers, data centers with low PUE requirements, local hot spots in computer rooms, high heat density areas in medium and large computer rooms, and computer rooms Data centers with tight area, etc.


    Applications

    • Single row cabinet data center
    • Single row cabinet and closed cold aisle data center
    • Closed hot aisle data center
    • Modular DC
    • Container type DC
    • DC with low PUE
    • Hot spot reconstruction

    Features

    Cooling on demand

    • DC frequency conversion, 10%-100% refrigeration capacity stepless adjustment, high efficiency at part load;
    • High-efficiency EC fan, close to the rack to supply air, the fan can save 20%-30%;
    • The outdoor fan frequency conversion speed regulation, control the air volume according to the demand;
    • Stable dehumidification under a load as low as 10%, excellent performance

    Safe and reliable

    • The start-up current is small, which can reduce the impact on the power grid;
    • Expert self-diagnosis and fault warning function to ensure operation;
    • Fan N+1 redundant configuration, to avoid equipment operation obstacles caused by unexpected situations;
    • Dual power input, safer and more reliable

    Intelligent control

    • Standard RS485 interface, support ModBus protocol;
    • Optional Ethernet interface, support TCP/IP/SNMP protocol;
    • Optional remote monitoring module, which can remotely read unit information through web, WeChat, official account, and APP;
    • Can be connected to multiple temperature and humidity sensors, multiple point detection;
    • Only group control can realize unbalanced load area coordination

    Flexible configuration

    • Centralized condenser is optional, saving area up to 60%;
    • Fluorine pump natural cooling module is optional, making full use of low temperature natural cooling to save energy;
    • Optional double-sided 90-degree air supply mode


    Technical Parameter


    ModelCRA013ACRA020ACRA040ACRA050ACRA060A
    Air supplyFront/SideFront/SideFrontFrontFront
    Power supply380VAC/3Ph/50Hz
    Cooling capacity-KW13.226.742.653.363.9
    Sensible cooling-KW13.226.742.653.363.9
    Compressor
    RefrigerantR410A
    Quantity1
    Fan
    Fan typeEC Centrifugal fan
    Quantity45233
    Air volume-m3/h3200500088001100012500
    Heater
    Heat typePTC
    Capacity-KW23666
    Humidification
    Capacity-KW11.5333

    Certificates


    Factory Details


    Packing & Delivery


    Case


    Quality 20-40KW In-Row Air Conditioning Unit with EC Fan and R410A Refrigerant for Data Center Cooling for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hefei Coolnet power Co., ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)