Coolnet Rack-Mounted UPS Energy Efficient Power Backup System For Data Centers Critical Equipment

    Buy cheap Coolnet Rack-Mounted UPS Energy Efficient Power Backup System For Data Centers Critical Equipment from wholesalers
     
    Buy cheap Coolnet Rack-Mounted UPS Energy Efficient Power Backup System For Data Centers Critical Equipment from wholesalers
    • Buy cheap Coolnet Rack-Mounted UPS Energy Efficient Power Backup System For Data Centers Critical Equipment from wholesalers
    • Buy cheap Coolnet Rack-Mounted UPS Energy Efficient Power Backup System For Data Centers Critical Equipment from wholesalers
    • Buy cheap Coolnet Rack-Mounted UPS Energy Efficient Power Backup System For Data Centers Critical Equipment from wholesalers

    Coolnet Rack-Mounted UPS Energy Efficient Power Backup System For Data Centers Critical Equipment

    Ask Lasest Price
    Brand Name : COOLNET
    Model Number : CNER01-CNER20
    Certification : CE,ISO
    Price : USD 120-2200/unit
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 3000 unit per month
    Delivery Time : 5-10 working days
    • Product Details
    • Company Profile

    Coolnet Rack-Mounted UPS Energy Efficient Power Backup System For Data Centers Critical Equipment

    Online Rack Mount Uninterruptible Power Supply Ups 1KVA 3KVA 6kva 10kva 15kva 20kva


    High frequency on line 1 kVA ~ 20 kVA ( single phase inlet and single phase
    outlet/three phase inlet and single phase outlet/three phase inlet and three phase outlet)


    Flexible, reliable and perfect compatible server cabinet.


    Coolnet rack type UPS is the double transformation on-line technology, support more than 3 sets parallel work, and support the function of sharing battery pack when in parallel mode; online UPScan provide the optimal power environment for the load. Regardless of voltage accuracy, input noise filtering, zero switching time and compatible with the standard terms of service cabinet, Rack UPS is the best choice.

    Character and Advantage

    ♦Support LBS control in sync;
    ♦​Have the function of fan speeding control with intelligence;
    ♦​Comprehensive electrical isolation protection and bypass protection;
    ♦​Support bypass maintenance (three phase inlet and single phase outlet/three phase inlet and three phase outlet);
    ♦​Large LCD Chinese/English display interface, user friendly;
    ♦​Make automatic alarm, self-detection, find problems easily in time come true;
    ♦​Three - stage extended charge design to ensure superior battery performance;
    ♦​Only online UPS, and output high quality sine wave power that provide the user a better power supply protection;
    ♦​Wider range of input voltage that working under large fluctuations grid environment, can be in commercial power
    ♦​mode without switching to battery mode, which can protect the battery lifespan


    Design Concept

    ♦Long-term power supply design

    Rack UPS provide long backup time unit for users to choose: through configure different battery pack capacities, can meet the user's requirements for different backup time.

    ♦Can be used with large motor

    Wide input voltage and frequency range that make Rack UPS compatible with main brand generator. It expand the application environment, meanwhile effectively remove the harmful power made by the generator, also supply a pure, safe and stable power for the load.

    Configure standard battery module

    Rack UPS configured standard battery module(For user selection). Standard battery modules are used in high quality VRLA maintenance free lead-acid battery, with high battery quality to ensure the safety and reliability of UPS using.

    ♦Zero transition time

    When the city power outage or recovery, it do not need conversion time for the Rack UPS switching between the power mode and the battery mode, thus effectively ensuring the reliability of load operation and data storage.

    Input power factor correction

    Rack UPS have Input power factor correct function, the Input power factor can reach to above 0.99% under full loading condition,which protect use's grid environment from pollution.

    ♦DC Start

    In the case of power cut, if need to start computer or other load devices by Rack UPS,Rack UPS can use battery to carry on DC Start, so that make the use of Rack UPS more convenient and reliable.

    ♦Auto restart function

    Once the city power abnormal, it will enter into battery mode to supply power until the end of power supply, then the Rack UPS will shut down automatically; after the city power back to normal, UPS will activate

    ♦Configure smart slot

    Rack UPS equipped with an intelligent slot,users can purchase SNMP card or other general accessories. Make centralized monitoring and remote management functions come true through SNMP internet management.


    Data Sheet

    ModelCNER-1101(L)CNER-1102(L)CNER-1103(L)CNER-1106LCNER-1110L
    Capacity1KVA/0.8kW2KVA/1.6kW3KVA/2.4kW6KVA/4.8kW10KVA/8kW
    Input
    Connection ModeSingle Phase + Ground
    Input Voltage200/208/220/230/240VAC
    Voltage Range100~300VAC
    Frequency40~70Hz
    Power factor>0.99
    Output
    Output Voltage200/208/220/230/240VAC
    Voltage regulation±1%
    FrequencySynchronous correction range46~54Hz/56~64Hz
    Battery Model50Hz±0.1Hz/60Hz±0.1Hz
    Distortion (THDU)≤0.3%
    Peak Coefficient≥3:1
    Overload Capacity110%,convey to bypass after 1h;125%,convey to bypass after 10min;150%,convey to bypass after 1min.
    Time switchingElectric City/Battery0ms
    Inverter/Bypass<4ms (standard environment)0ms
    Battery
    Standard MachineBattery Cells246/
    Charging Current1.0A (Max)/
    Battery Model12V,9Ah/
    Long LastingBattery Cells36816(16-20 optional)
    Charging Current1A/2A/4A/6A settable
    Battery ModelDepends on the applicant
    Efficiency
    City Electricity Model>91%>93%
    Battery Model>91%>93%
    Display Interface
    LCD/LEDLoading Size, Battery Capacity, City Electricity Mode, Battery Mode, Bypass Mode, Fault Indication
    Control Management
    Intelligent RS-232/USBSupport Windows 2000/2003/XP/Vista/2008,Windows 7/8,Linux,Unix and MAC
    Option SNMPSupport SNMP Internet Management
    Environment
    Temperature0~40℃
    Relative Humidity0~95% (Non Condensing)
    Noise<50dB@1m<55dB@1m<58dB@1m
    Physical Character
    Standard MachineSize: Width*Depth*Height(mm)438*310*88438*410*88438*630*88//
    Net Weight(kg)121829//
    Long LastingSize:Width*Depth*Height(mm)438*310*88438*410*88438*530*88438*580*133
    Net Weight(kg)5781216

    ModelCNER-3110LCNER-3115LCNER-3120L
    Capacity10kVA/8kW15kVA/12kW20kVA/16kW
    Input
    Connection ModeThree-phase + four wire
    Rated Voltage380/400/415VAC
    Voltage Range285~520VAC@100%Load; 176~520VAC@50%Load
    Frequency40~70Hz
    Power factor≥0.99
    Output
    Output Voltage200/208/220/230/240VAC
    Voltage regulation±1%
    FrequencySynchronous correction range46~54Hz/56~64Hz
    Battery Model50Hz±0.1Hz/60Hz±0.1Hz
    Distortion (THDU)≤2%( Linear load ), ≤3% ( Non-liner load )
    Distortion (THDU)≤0.3%
    Peak Coefficient≥3:1
    Overload Capacity110%, convey to bypass after 1h; 125%, convey to bypass after 10min; 150%, convey to bypass after 1min.
    Time switchingElectric City/Battery0ms
    Inverter/Bypass0ms
    Battery
    Battery Cells20
    Charging Current1A/2A/4A/6A Settable
    Battery ModeDepends on the applicant
    Efficiency
    City Electricity Mode / Battery Mode≥93%
    ECO Mode≥96%
    Display Interface
    LCD/LEDLoading Size, Battery Capacity, Electric City Mode, Battery Mode, Bypass Mode, Fault Indication
    Control Management
    Intelligent RS-232/USBSupport Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix and MAC
    Option SNMPSupport SNMP Internet Management
    Environment
    Temperature0~40℃
    Relative Humidity0~95% (Non Condensing)
    Noise<60dB@1m<65dB@1m
    Physical Character
    Size: Width*Depth*Height(mm)438*668*133438*668*266
    Net Weight(kg)2245
    ModelX1-3110LX1-3115LX1-3320L
    Capacity10kVA/8kW15kVA/12kW20kVA/16kW
    Input
    Connection ModeThree-phase + four wire
    Rated Voltage380/400/415VAC
    Voltage Range285~520VAC@100%Load; 176~520VAC@50%Load
    Frequency40~70Hz
    Power factor≥0.99
    Output
    Output Voltage380/400/415VAC
    Voltage regulation±1%
    FrequencySynchronous correction range46~54Hz/56~64Hz
    Battery Model50Hz±0.1Hz/60Hz±0.1Hz
    Distortion (THDU)≤2 %( Linear load ), ≤3% ( Non-liner load )
    Distortion (THDU)≤0.3%
    Peak Coefficient≥3:1
    Overload Capacity110%, convey to bypass after 1h; 125%, convey to bypass after 10min; 150%,convey to bypass after 1min.
    Time switchingElectric City/Battery0ms
    Inverter/Bypass0ms
    Battery
    Battery Cells20
    Charging Current1A/2A/4A/6A Settable
    Battery ModeDepends on the applicant
    Efficiency
    City Electricity Mode / Battery Mode≥93%
    ECO Mode≥96%
    Display Interface
    LCD/LEDLoading Size, Battery Capacity, Electric City Mode, Battery Mode, Bypass Mode, Fault Indication
    Control Management
    Intelligent RS-232/USBSupport Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix and MAC
    Option SNMPSupport SNMP Internet Management
    Environment
    Temperature0~40℃
    Relative Humidity0~95% (Non Condensing)
    Noise<60dB@1m<65dB@1m
    Physical Character
    Size: Width*Depth*Height(mm)438*668*133438*668*266
    Net Weight(kg)4346